FDH Electronics |
|||
Shipping Address: |
Billing Address: |
Toll Free: 800. 324.6591 |
DESIGNED TO DELIVER THE INVENTORY YOU NEED
Mil-Spec No. | MIL-W-5086 |
---|---|
Gauge | 3/0 |
Stranding | 1665/30 |
Nom. Outer Diameter | 0.650 |
Operating Voltage | 600 V |
Temperature Rating | 105 ºC |
Conductor | Tinned Copper |
Insulation | Polyvinylchloride (PVC) Fiberglass Braid |
Jacket Material | Clear Nylon 22-10 gauge Nylon Impregnated Braid 8-4/0 gauge |
Color | White - stripes are available for color coding In accordance with MIL-STD-104, Class 1; white preferred |
Stranding (Number of Strands X AWG gage of Strands) | 1665 x 30 |
Min. Diameter of Stranded Conductor | 0.500 in |
Max. Diameter of Stranded Conductor | 0.540 in |
Max. Resistance at 20ºC (68ºF) per 1000 ft. | 0.071 ohms |
---|---|
Diameter | 0.650 ± 0.015 in |
Max. Weight | 620.00 lb/1000 ft. |
Mandrel Diameter (±3%) - Life Cycle (Oven and Bend Tests) | 10.00 in |
---|---|
Mandrel Diameter (±3%) - Cold Bend Test | 18.00 in |
Test Load (±3%) - Life Cycle (Oven and Bend Tests) | 10.00 lb |
---|---|
Test Load (±3%) - Cold Bend Test | 30.00 lb |
Max. Conductor Temperature Range | 221 ºC 105 ºF |
---|---|
Blocking | 105 ±2 ºC 221 ±3.6 ºF |
Color Striping or Banding Durability | 50 cycles (100 strokes) (min), 250 grams weight |
Flammability (Method 1) | 30 sec (max) after-flame 1.50 inches (max) flame travel, either direction on wire No flaming of tissue paper |
Identification Durability | 50 cycles (100 strokes) (min), 250 grams weight |
Impulse Dielectric Test | Primary Insulation (When Test is used in Lieu of Spark Test): 6.0 kilovolts (Peak), 100% Test Finished wire: 8.0 kilovolts (peak), 100% test |
Life Cycle (Oven Temperature) | 120 ±2 ºC 248 ±3.6 ºF |
Low Temperature (Cold Bend) | -55 ±2 ºC -67 ±3.6 ºF |
Shrinkage | 0.125 inch Max. @ 150º ±2ºC (302º ±3.6ºF) |
Smoke | 110 ºC 230 ºF |
Spark Test of Primary Insulation | 4000 volts (rms), 60 Hz, 100% test |
Thermal Shock (Oven Temperature) | 105 ±2 ºC 221 ±3.6 ºF |
Wet Dielectric Test | 2000 V RMS |
Note | In the selection of MIL-W-5086/2 wire specimens for the wrap test, each sample length from which a specimen is to be taken shall first be subjected to the dye inspection described under the wrap test procedure of MIL-W-5086, in order to detect glass fiber protrusions, if present, which permit dye penetration into the underlying braid. Specimens for the wrap test shall be cut only from those portions of each sample length which are free of such glass fiber protrusions. |
---|